MODEL 5100-02-IT
IT Series
COMBUSTIBLE GAS SENSOR MODULE
Version 2.00a
APPLICABILITY & EFFECTIVITY
Effective for all Model 5100-02-IT Modules manufactured after February 15, 2008.
Instruction Manual Part Number T12019
Rev. B1
Zobrazit stránku 0
1 2 3 4 5 6 ... 40 41

Shrnutí obsahu

Strany 1 - IT Series

MODEL 5100-02-IT IT Series COMBUSTIBLE GAS SENSOR MODULE Version 2.00a APPLICABILITY & EFFECTIVITY Effective for all Model 5100-02-IT Modules

Strany 2

Model 5100-02-IT Combustible Gas Sensor Module Page: 8 2.3.1 CATALYTIC BEAD SENSOR MODULES Model 5100-02-IT Gas Sensor Modules are FM performance ap

Strany 3

Model 5100-02-IT Combustible Gas Sensor Module Page: 9 3. INSTALLATION NOTE All IT modules are factory pre-configured and calibrated. All modules are

Strany 4

Model 5100-02-IT Combustible Gas Sensor Module Page: 10 3.3 ENCLOSURE INSTALLATION To protect the transmitter and sensor assembly they should be rem

Strany 5 - 1. PRODUCT DESCRIPTION

Model 5100-02-IT Combustible Gas Sensor Module Page: 11 6. Carefully return the transmitter to the enclosure installing it over the two standoffs.

Strany 6

Model 5100-02-IT Combustible Gas Sensor Module Page: 12 Figure 3-2 Connector Locations 3.5 INSTALLATION CONFIGURATION Table 3-3 and Figures 3-1 thro

Strany 7

Model 5100-02-IT Combustible Gas Sensor Module Page: 13 Figure 3-3 4-20 mA Connection

Strany 8

Model 5100-02-IT Combustible Gas Sensor Module Page: 14 Figure 3-5 Remote Alarm Reset Figure 3-4 Digital Interface Connections

Strany 9 - 2. CAUTIONS & WARNINGS

Model 5100-02-IT Combustible Gas Sensor Module Page: 15 Figure 4-6 HMI Switch Locations 4. INTRODUCTION – HUMAN-MACHINE INTERFACE SYSTEM The Combust

Strany 10

Model 5100-02-IT Combustible Gas Sensor Module Page: 16 4.2 MAIN MENU Table 4-1 describes the primary human-machine interface operation. Function Di

Strany 11 - 3. INSTALLATION

Model 5100-02-IT Combustible Gas Sensor Module Page: 17 4.3 CONFIGURE SET-POINTS The sensor module set-points menu is used to initially set-up the a

Strany 12

Model 5100-02-IT Combustible Gas Sensor Module FM APPROVAL ONLY THE FOLLOWING ITEMS, FUNCTIONS AND OPTIONS ARE FM* APPROVED Model 5100-02-IT Combu

Strany 13 - UNCTION P2 FUNCTION

Model 5100-02-IT Combustible Gas Sensor Module Page: 18 Function Display Description ReferenceM ESTM ESTM ESTM ESTMES TMES TMES TMES TM ESTM ESTUse S

Strany 14

Model 5100-02-IT Combustible Gas Sensor Module Page: 19 M ESTM ESTM ESTM ESTM ESTM ESTM ESTM ESTMES TM ESTM ESTM ESTM ESTM ESTM ESTM ESTM ESTM ESTM E

Strany 15 - 4-20 mA Connection

Model 5100-02-IT Combustible Gas Sensor Module Page: 20 4.4 MAINTENANCE FUNCTIONS The maintenance menu allows the operator to monitor certain Sensor

Strany 16

Model 5100-02-IT Combustible Gas Sensor Module Page: 21 5. CALIBRATION 5.1 CALIBRATION FREQUENCY The manufacturer specifies that sensor modules must

Strany 17 - E : ENTER

Model 5100-02-IT Combustible Gas Sensor Module Page: 22 FunctionDisplay Description ReferenceM ESTM ESTM ESTM ESTM ESTM ESTM ESTMES TMES TM ESTMES

Strany 18 - Page: 16

Model 5100-02-IT Combustible Gas Sensor Module Page: 23 6. SERVICE 6.1 SENSOR MODULE CONFIGURATION The gas sensor module is comprised of the follow

Strany 19

Model 5100-02-IT Combustible Gas Sensor Module Page: 24 6.3 TRANSMITTER REPLACEMENT The transmitter assembly should be replaced when it is determine

Strany 20 - Page: 18

Model 5100-02-IT Combustible Gas Sensor Module Page: 25 • Wiring terminations clean and correct. 6.5.4 MOISTURE TRAPS AND RAINSHIELDS • Conduit se

Strany 21 - Page: 19

Model 5100-02-IT Combustible Gas Sensor Module Page: 26 7. APPENDICES 7.1 APPENDIX A: SPECIFICATIONS Specifications: Sensor: Type: Catalytic Be

Strany 22

Model 5100-02-IT Combustible Gas Sensor Module Page: 27 7.2 APPENDIX B: MODEL NUMBERS & PARTS LIST Sensor Module 5100-02-IT-AL Sensor Module, C

Strany 23 - 5. CALIBRATION

Model 5100-02-IT Combustible Gas Sensor Module Contents TABLE OF CONTENTS 1. PRODUCT DESCRIPTION ...

Strany 24 - Page: 22

Model 5100-02-IT Combustible Gas Sensor Module Page: 28 7.3 APPENDIX C: LIMITED WARRANTY SIERRA MONITOR CORPORATION warrants its products to be free

Strany 25 - 6. SERVICE

Model 5100-02-IT Combustible Gas Sensor Module Page: 29 7.4 APPENDIX D: REMOTE SENSOR DRAWING 5394-50

Strany 26

Model 5100-02-IT Combustible Gas Sensor Module Page: 30 7.5 APPENDIX E: AUXILIARY RELAY ASSEMBLY 5394-62

Strany 27

Model 5100-02-IT Combustible Gas Sensor Module Page: 31 7.6 APPENDIX F: AUXILIARY CONNECTION ASSEMBLY 5394-61

Strany 28 - Specifications:

Model 5100-02-IT Combustible Gas Sensor Module Page: 32 7.7 APPENDIX G: AUXILIARY RS-485 MULTIDROP ASSEMBLY 5394-64

Strany 29 - Page: 27

Model 5100-02-IT Combustible Gas Sensor Module Page: 33

Strany 30

Model 5100-02-IT Combustible Gas Sensor Module Page: 34 7.8 APPENDIX H: MODBUS MEMORY MAP Read Register Table Register Description Comments 40001

Strany 31 - Page: 29

Model 5100-02-IT Combustible Gas Sensor Module Page: 35 7.9 APPENDIX I: COMBUSTIBLE GAS SCALING FACTORS For combustible gas monitoring, a calibratio

Strany 32 - Page: 30

Model 5100-02-IT Combustible Gas Sensor Module Page: 36 7.10 APPENDIX J: Menu Key for 5100-02-IT Gas Sensor Module • Key M : MODE • Key E : ENT

Strany 33 - Page: 31

Model 5100-02-IT Combustible Gas Sensor Module Page: 37 SETUP MENU Once in the SETUP menu use the ▲ or ▼ keys to access each of the 5 main sections

Strany 34 - Page: 32

Model 5100-02-IT Combustible Gas Sensor Module Contents 6.2 ENCLOSURE REPLACEMENT ...

Strany 35

Model 5100-02-IT Combustible Gas Sensor Module Page: 38 | |----▼ 4-20mA (Verifies 4mA or 20mA output and selects condition of output during calibrat

Strany 36

Model 5100-02-IT Combustible Gas Sensor Module Page: 39 THIS PAGE INTENTIONALLY LEFT BLANK

Strany 37

Model 5100-02-IT Combustible Gas Sensor Module Page: 3 1. PRODUCT DESCRIPTION 1.1 GENERAL The Model 5100-02-IT Catalytic Bead Combustible Gas Sensor

Strany 38

Model 5100-02-IT Combustible Gas Sensor Module Page: 4 Figure 1-2 Model 5100-02-IT Combustible Gas Sensor Module Aluminum – Dimensions Figure 1-1 M

Strany 39 - SETUP MENU

Model 5100-02-IT Combustible Gas Sensor Module Page: 5 1.4.2 MODBUS OPERATION All IT gas sensor modules have a Modbus RTU RS-485 serial interface t

Strany 40

Model 5100-02-IT Combustible Gas Sensor Module Page: 6 1.6 INTERCONNECT WIRING Not supplied with the sensor module, but necessary to the installatio

Strany 41

Model 5100-02-IT Combustible Gas Sensor Module Page: 7 2. CAUTIONS & WARNINGS 2.1 INTRODUCTION Although IT Transmitter Modules are designed and